RAID 5
(striping with interspersed parity). Allows one hard disk to fail or being unplugged.
RAID 6
(2-dimensional parity protection). RAID 6 allows two hard disks to fail or being unplugged. If two hard disks need to be rebuilt at
the same time, it will rebuild the rst one and then the other one.
RAID 0+1
(mirroring of the member RAID 0). Allows two hard disks to fail or being unplugged, but the hard disks must in the same array.
RAID 10
(striping over the member RAID 1). Allows two hard disks to fail or being unplugged, but the hard disks must in different array.
RAID 30
(striping over the member RAID 3). Allows two hard disks to fail or being unplugged, but the hard disks must in different array.
RAID 50
(striping over the member RAID 5). Allows two hard disks to fail or being unplugged, but the hard disks must in different array.
RAID 60
(striping over the member RAID 6). Allows four hard disks to fail or being unplugged, but no more than two hard disks in same
array.
JBOD
The abbreviation of “Just a Bunch Of Disks”. No data protection. Data is damaged or inaccessible if any hard disk fails or is
unplugged.
5.2 VG Migration and Expansion
VG Migration/Expansion allow you to change from one RAID level to another, or expand current RAID
level to additional Hard drives. To migrate the RAID level, follow the steps below.
1. Click “/Volume con g/Volume group”
2. Select the VG to be migrated and click “ ” button in the RAID eld
3.
Change the RAID level by clicking the “ ” down list. If the hard disk capacity is not enough
to support the new RAID level, a request to add more PD will pop up. Click “
to add hard disks and click
” to go back to the con gure page.
When migrating to lower RAID level, such as the migration from RAID 6 to 0, data will be lost. the
system will evaluate if this operation is safe and display the “Sure to migrate to a lower protection
array?” to warn you.
4. Double check the con guration. If there is no change needed, click “ ”.
5.
A con rmation page will show detailed RAID data. If there is no change needed, click “
to start the migration.
6.
In the “status 3” eld, you can view the migration status and the letter “M” will be displayed. In “/Volume
con g/User data volume”, a “M” and progress percentage “R%” will be displayed in “Status 3”.
Figure 5.2.1
Remind : To migrate/expand, the total volume of VG must be larger or equal to the original VG. It does not allow the hard
disks with the same RAID level and the same original VG to expand.
When con guring the migration, if the settings are incorrect, the system will pop up a warning window described as below:
"Invalid VG ID": Source VG error
"Degrade VG not allowed": Source VG is degraded
"Initializing/rebuilding operation's going": Source VG is initialing or rebuilding
"Migration operation's going": Source VG is doing migration
"Invalid VG raidcell parameter": Structural error. For example, the size of a new VG is smaller than that of the original VG
Note : VG migration cannot be executed during data rebuilding or UDV expansion.
SANS DIGITAL
RAID Introduction 51